Idex Home Page

Design/Application Request | Distributors | Web Store | Contact Us

Advanced Search | Product Locator

Polysulfone

In general, polysulfone is chemically resistant and can be used in many applications. There are some chemicals, however, that should not be used. Primarily, chlorinated organic solutions should be avoided, as should some alcohols and some aromatic hydrocarbons.

Temperature Range up to 100 °C
Thread Strength Excellent
Oxygen Permeability 230cc / 100in2 * 24h * atm / mil @ 25 °C
pH Range 0 - 14
Sterilization Techniques  
Autoclavable? Y

Polysulfone Extended Properties

General   Comments Units  
Water Absorption 24 hours ASTM D570 % 0.03
Density   ASTM D792 g/cc 1.24
Mechanical   Comments Units  
Tensile Strength Yield ASTM D638 psi 10,153
Elongation Break 50 - 100%
Yield
ATSM D638
ATSM D638
%
%
75
6
Modulus of Elasticity GPa ASTM D638 ksi 360
Flexural Modulus GPa ATSM D790 ksi 390
Flexural Yield Strength MPa ATSM D790 ksi 15,374
Impact Strength Izod, J/cm Notched ATSM D256 ft-lb/in 1.3
Tensile Impact Strength kJ/m2 - ft-lb/in2 200
Thermal   Comments Units  
Coefficient of Linear Thermal Expansion 20 °C Tansvers to Flow, µm/m- °C in flow; ASTM E381
ASTM E381
µin/in- °F
µin/in- °F
31
31
Deflection Temp at 1.8 MPa, °C ASTM D648 °F 345
Maximum Continuous Temperature UL Relative Thermal Index, Electrical per UL 746B. Mechanical with impact 140 °C (280 °F); Mechanical without impact 160 °C(320 °F) °F 320
UL RTI Electrical, °C
Mechanical with Impact, °C Mechanical without impact, °C
at 0.51mm
at 0.51mm
at 0.51mm
°F
°F
°F
320
284
284
Flammability UL94 5=V-0; 4=V-1; 3=V-2; 1=HB HB @ 1.47mm HB 1
Electrical   Comments Units  
Electrical Resistivity   ASTM D257 ohm-cm 5E+16
Dielectric Constant at 1kHz
Low Frequency, 1kHz
ASTM D150
ASTM D150
-
-
 
Dielectric Strength   ASTM D149 kV/in 432
Dissipation Factor at 1kHz
Low Frequency, 1kHz
ASTM D150
ASTM D150
kHz
kHz
0.0015
0.0015